Hi Tom,
Is there any way one could monitor oxygen sensor data? If not, is there any chance that this could be added to the program?
Cheers,
KLW
KNOCK SENSOR DATA
KNOCK SENSOR DATA
Last edited by Uenuku85 on 07 Feb 2014, 14:48, edited 1 time in total.
Re: Oxygen sensor data
Sorry, I meant to say knock sensor. Is there anyway that we could get live data from the knock sensor?
Cheers
KLW
Cheers
KLW
Re: KNOCK SENSOR DATA
There is no way to monitor the knock sensor at this stage. The Consult II protocol just doesn't have such function. Which is a shame.
It might be possible to do it using the "Address Watch" function but you would need to know the memory address that stores the knock sensor value. I haven't been able to find one yet.
It might be possible to do it using the "Address Watch" function but you would need to know the memory address that stores the knock sensor value. I haven't been able to find one yet.
Re: KNOCK SENSOR DATA
No worries. Thanks, Tom.
Also, what is NB sens b1? I can't figure out what this value is.
Thanks again,
KLW

Also, what is NB sens b1? I can't figure out what this value is.
Thanks again,
KLW
Re: KNOCK SENSOR DATA
Sorry, how do you determine the memory address?
Re: KNOCK SENSOR DATA
NB sens b1 - Narrow Band O2 sensor bank 1
You have to de disassemble the ECU software to find the RAM address.
You have to de disassemble the ECU software to find the RAM address.
Re: KNOCK SENSOR DATA
Cool. Thanks.
Ah. Sounds fun!
Ah. Sounds fun!
-
- Posts: 78
- Joined: 10 Jan 2012, 06:45
- Location: France
Re: KNOCK SENSOR DATA
damage, it is an important parameter